Our overall concept consists of a 6U x 6HP x 160mm ruggedized Plug in Power System. The system also contains over voltage, over current, over temperature and short circuit protection. The UPS system has been designed to comply with all of the radiated emissions, susceptibility and conductive emissions requirement of the applicable sections of MIL-STD-461E. These techniques have been used successfully by AJPS to comply with these standards many times in the past. The following is a list of methods used for controlling emissions:
The unit will be designed to meet MIL-STD-461E all testing will be the responsibility of the customer.
This power supply also has an NED Circuit.
The assembly will provide an internal Nuclear Event Detector (NED) with an output voltage crowbar circuit. The internal NED circuit shall consist of a SCR (part number 2N2324) with a 1k ohm (+/-1%) resistor connected from SCR Gate to Cathode. In parallel with the 1k resistor shall be a .01µF ceramic capacitor. When the SCR is triggered, the power supply shall shut off and crowbar the +5V, +3.3V, 12V isolated, and +/‑12V outputs to less than 35% of nominal voltage within 400µs. Following nuclear event detector SCR trigger, the power supply shall remain off until +28V input power is cycled off then on.
The assembly will also accept an external NED_DR signal referenced to +28V_RTN. When the NED_DR signal is open circuit or less than 4V, the power supply shall operate normally. When the NED_DR signal is connected to +28V input power for 100µs minimum, the nuclear event detector SCR shall trigger, shut off the power supply, and crowbar the output voltages. Following nuclear event detector SCR trigger, the power supply shall remain off until +28V input power is cycled off then turned on. The NED_DR input shall have an input impedance of 20k (+/‑10k) ohms.
Data Specifications
Item | Unit of Measure | |
Input Voltage | VDC | 16 to 32 VDC per MIL-STD-1275 |
Output Voltage | VDC | 5 VDC at 60 Watts 12 VDC at 12 Watts -12 VDC at 12 Watts 3.3VDC at 6.6 Watts Isolated 12VDC at 5 Watts Pass though 28VDC at .5 Amps |
Start Time | seconds | < 1 Seconds |
Efficency | % | >75% |
Name Plate | Per MIL-STD-130 | |
Unit Identification | Per MIL-STD-130 | |
Physical Dimensions | 6U x 12HP x 160mm | |
Cooling | Conduction Cooling through Wedge Locks | |
Weight | lbs | < 5 Lbs – 3Lbs Target Weight |
Environments
Item | Unit of Measure | |
Alltitude | Ft | 10,000Ft Operating 40,000 Non Operating |
Temperature | ºC | -40 to 85C Base Plate |
Humidity | % | 90% non condensing |
Fungus | MIL-STD-810F Method 508* | |
Salt Fog | MIL-STD-810F Method 510* | |
Sand, Dust, and Volcanic Ash | MIL-STD-810F* | |
Vibration | MIL-STD-810F* / TBD | |
Functional Shock | MIL-STD-810F* / TBD |
*Compliance via analysis or similarity.