MIL-CDRSeriesTM

MODEL NUMBER CONFIGURATION

MIL-CDR-V-W

Voltage Wattage
A = 115 100
B = 230 400
C =   800
D =   1200

AJ’s Power Source Inc. (AJPS) Cage Code (0P327) is pleased to announce the release of our new MIL-CDRSeries. This new series is a Ruggedized Military compliant power conditioning system built for deployment and operations equipment. These units are available to all military, homeland security and government contractors. Built for a Very Low EMI signature and very High Reliability this power system will keep your product up and running for many years to come.

The MIL-CDRSeries is a 1U power conditioning system that provides up to 800 Watts at 115 VAC 60Hz. This is a fully isolated in line double conversion system with input surge protection. This system has many unique features such as over voltage, over current, over temperature and short circuit protection. Stainless steel side rails allow for multiple rack depths and the system has field replaceable filters and fans. This system also contains a 24VDC emergency input that will allow for the system to be powered from any 24VDC source if or when AC inputs are not available.

Power Conditioner

We Can Customize to Suit Your Need

Contact us to discuss a solution for you or
email us directly to requst a quote.

Request a Quote

 


EMI/EMC

The conditioner system has been designed to comply with all of the radiated emissions, susceptibility and conductive emissions requirement of the applicable sections of MIL-STD-461E. These techniques have been used successfully by AJPS to comply with these standards many times in the past. The following is a list of methods used for controlling emissions:

  1. Metal Chassis with gaskets on all non sealed interfaces
  2. EMI Filters on all input and output power lines
  3. Internal circuitry shielded and isolated
  4. Ground Planes used for noise isolation
  5. Connectors area isolation from Conversion Area
  6. External line filter and shielded cables required

AIR FILTERS

Air filters should be placed on a regular maintenance schedule. Suggested inspection should be once a month for any outdoor or high dust environment. The filters can be washed with warm water and soap or blown out in the reverse direction with an air compressor. Regardless of cleaning and inspection processes the filters should be replaced one a year minimum.

FAN MODULES

The systems rear fans have been design for field replacement and only need replacement in the event of a failure. These fans should be inspected at the same time that the filters are cleaned or changed. If one of the fans is operating slowly, stuttering, or stopped the assembly must be replaced.

OUTPUT POWER CABLES

Output power cables are available upon request. The output power cable will need to be shielded from source to termination if system is required to meet MIL-STD-461E.


Data Specifications

Item Unit of Measure  
Input Voltage VAC 100-264, 47-440Hz
Efficiency % 80 % Typical
Hold Up Time mS >16 mS at 80% Load
Operating Temperature ºC –20 to 60ºC
Storage Temperature ºC -40 to 85ºC
Over Voltage Protection % 130% Standard
Short Circuit Protection % 130% Standard
Thermal Protection Standard Over Temperature Shut down 70ºC +/- 5ºC
Humidity % 5-95% Non-Condensing
Altitude Ft 10,000 Ft
Isolation 1500 VDC Input to Ground and Input to Output

Output Specifications

Item Unit of Measure  
Output Voltage VAC 115 VAC or 220 VAC
Output Power W 800 Watts
Output Frequency Hz 50Hz +/- .2Hz or 60Hz +/- .2Hz
Control and Status % SNMP
Harmonic Distortion % <2% with resistive load

 

MILITARY STANDARDS

MIL-STD-810F

  • Humidity
  • Altitude
  • Sand and Dust
  • Shock and Vibration
  • Temperature

MIL-STD-461E

  • RE101, RE102,CE101, CE102, CE103

MIL-STD-882D
MIL-STD-1472F
MIL-STD-1474D

* Units are designed to meet these standards but, each unit must be tested at system level. Shielded cables and line filters required.